Searching for UPS dealers in Bangalore for reliable power backup? Explore Cosmic® Online UPS systems designed to protect critical equipment in offices, IT facilities, healthcare environments, retail spaces and industrial units. Our double-conversion UPS solutions help maintain a stable power supply during voltage fluctuations and interruptions. Contact Cosmic® to discuss the right configuration for your load and backup requirements.
From small offices to industrial facilities, power continuity matters. Cosmic® Online UPS systems are designed to support essential operations by conditioning incoming power and providing battery-backed output when the mains supply is interrupted. If you are comparing UPS suppliers in Bangalore, consider the load capacity, phase configuration, required runtime, battery type and maintenance needs before choosing a system.
Servers, networking devices and workstations can be sensitive to unstable power. A properly sized online UPS can help reduce interruptions and protect critical infrastructure. Cosmic® UPS solutions may be configured for server rooms, networking racks, computer labs and office equipment, subject to load assessment.
Factories and commercial installations often require dependable backup for controls, monitoring equipment and other essential loads. Cosmic® offers online UPS configurations for a range of industrial and commercial requirements. Our listed product specifications include single-phase and three-phase options; availability depends on the selected model.
UPS sizing should be based on total connected load, starting or peak demand, required backup time and the electrical installation. Cosmic® advertises online UPS systems across a broad capacity range, including solutions for smaller commercial loads and larger installations. The technical specification table below describes the listed 5 kVA–250 kVA configurations; confirm the specifications for the exact model before ordering.
Cosmic® focuses on double-conversion online UPS technology, regulated output and flexible configurations for business-critical power protection. When requesting a quotation, share your location in Bengaluru, connected equipment, preferred backup duration and phase requirement so the team can recommend a suitable solution. Confirm delivery, installation and after-sales service coverage for your address directly with Cosmic®.
Looking for an online UPS dealer or supplier for your Bangalore project? Use the enquiry form to request product details, capacity recommendations and a quotation from Cosmic®.
| DESCRIPTION | ON – LINE UPS |
|---|---|
| TECHNOLOGY | Advance PWM with high Frequency Switching DSP based Double conversion, Isolated output |
| CAPACITY | 5KVA – 250 KVA (1Ph – 1Ph) (3Ph – 1Ph) (3Ph – 3Ph) |
| Voltage | 160v – 280V AC |
|---|---|
| Frequency | 50Hz +- 5Hz |
| Voltage | 225V / 415 V AC |
|---|---|
| Frequency | 50Hz +- 0.1Hz |
| Regulation | 225V / 415V +- 1% |
| Wave Form | Pure Sine Wave |
| Power Factor | 0.8 Lag |
| Distortion | Less than 2% |
| Inverter | By Using IGBT Devices |
| Load Crest Factor | Up to 3:1 |
| Noise Level | Less than 40db |
| Withstanding Capacity | 150% Over Load for 60secs |
| Type of Cooling | Forced Air Cooling |
| Type of Charging | Boost Cum Trickle ( by using IGBT Devices) |
| Efficiency | Better than 95% on Inverter, Above 92% as overall |
| Input | Over Voltage / Under Voltage / Spikes / Surges |
|---|---|
| Battery | Over Charge / Low Voltage (Deep Discharge) |
| Output | Over Voltage / Under Voltage / Over load / Short Circuit |
| INDICATIONS | Mains on / Inv. On / Inv. Trip / Batt. Low / Inv. U/V – O/V Trip |
| ALARMS | Battery Low / Mains Failure |
| LCD DISPLAYS |
Input Volt / Output Volt / Output Current / Output Freq Battery Volt / Battery Current |
| Type | Lead Acid – Inverter / Tubular / SMF |
|---|---|
| Battery Voltage | 48V – 360V |
| Recharging Time | 8 to 10 Hrs |
| Back Up Provisions | 10 Min. to 24 Hrs. |
| OPTIONAL FEATURES | Static Switch / Hot Standby / SNMP |
You can contact Cosmic® through the enquiry form on this page to discuss Online UPS requirements for a Bangalore location. Confirm local supply, delivery and installation availability with the team.
The right capacity depends on your connected load, power factor, backup duration and any peak demand. Share your equipment list with Cosmic® for a model-specific recommendation.
Online UPS systems are commonly used for servers, networking equipment and workstations because double-conversion technology supplies regulated power. Suitability depends on correct sizing and configuration.
Cosmic® lists online UPS configurations for industrial applications, including three-phase options. Contact the team to confirm the required model, delivery area and support arrangements.
Capacity, phase configuration, battery bank, required runtime, installation requirements and optional features all influence pricing. Request a quotation for your exact needs.
An online UPS continuously converts AC power to DC and back to AC, providing regulated output with no transfer delay in normal operation. A line-interactive UPS typically switches to battery power when necessary.